Sign In | Join Free | My fazendomedia.com
China Jufu Water Technology Co., Ltd logo
Jufu Water Technology Co., Ltd
Water Treatment Equipment Expert Worldwide!
Active Member

3 Years

Home > Drinking Water Treatment System >

500LPH One Stage RO Drinking Water Systems Water Purification Plant

Jufu Water Technology Co., Ltd
Contact Now

500LPH One Stage RO Drinking Water Systems Water Purification Plant

Brand Name : Jufu

Model Number : JFD-500L

Certification : ISO9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time : 2-4 weeks

Packaging Details : Export standard wooden box (like plywood), no need to fumigate, really suitable for shipping.

Tank material : SS/FRP (optional)

Warranty : 1 Year

Capacity : 500L/H

Type : One stage RO

Function : Water Purification machine

Recovery : 50%

Desalination rate : ≥99.5%

Product name : RO machine

Contact Now

500LPH One Stage Drinking Water Reverse Osmosis System Water Purification Plant

What are the types of membranes for drinking water ro systems?

1. Cellulose acetate reverse osmosis membrane. Cellulose acetate is also called acetyl cellulose or cellulose acetate. Cellulose acetate is usually obtained from cotton and wood containing cellulose through esterification and hydrolysis, and then processed into reverse osmosis membrane.

2. Composite reverse osmosis membrane. The composite reverse osmosis membrane is mainly composed of the above two materials, consisting of a thin dense layer and porous support layer. The porous support layer, also known as the base membrane, enhances mechanical strength. The dense layer, also called the epidermis, plays a role in desalting, so it is also called the desalting layer. The thickness of seawater desalination layer is generally 50nm, and the thinnest is 30nm.

3. Polyamide reverse osmosis membrane. Polyamides include aliphatic and aromatic polyamides. The main applications in the 1970s were aliphatic polyamides, such as nylon-4, Nylon-6 and Nylon-66 membranes.

Since the pore size of the RO membrane is one millionth of the hair (0.0001 micron), it is generally invisible to the naked eye, and bacteria and viruses are 5000 times larger than it. Therefore, only water molecules and some mineral ions can pass through (the ions that pass through) No profit or loss orientation), other impurities and heavy metals are discharged from the waste water pipe.

Technical specifications for reverse osmosis systems for drinking water:

0.5m³/h Reverse Osmosis System
Model JFRO-500L
Host Size 800x600x1600mm (can be customized)
Power 1.5KW
Power Supply 220V /380V/460V - 50Hz/60Hz,220V 50Hz can be customized
Operating Pressure 0.8-1.2MPa
Recovery Rate 50%
Designed Water Inlet 1000L/h
Outlet Flow 500L/h
Desalination Rate ≥99.5%
RO Frame SUS304
Membrane Size 4040
Membrane Elements DOW /Hydranautics/Troy/ Vontron (Optional)
Number of Membranes 2
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
Raw Water Pump CNP/NYP/GRUNDFOS (Optional)
Tank Material SS/FRP (Optional)
Control Valve Manual/Automatic
Control Valve Brand FLECK/RUNXIN
Membrane Housing SS/FRP (Optional)
Pipe Material U-PVC, Stainless steel (Optional)

Drinking water RO system work flow chart:

500LPH One Stage RO Drinking Water Systems Water Purification Plant

Cleaning of reverse osmosis membranes

A. Cleaning method Dilute the cleaning agent to a certain concentration and pump it into the membrane module for cleaning. In the case of serious pollution, the method of soaking overnight can be used, but the time should not be too long; the contact time between the chemical agent and the membrane should be minimized.
B. Calcium carbonate scale Reduce the pH value of the feed water to between 3.0 and 5.0, and run for 1 to 2 hours.
C. Calcium sulfate scale The best way to remove the scale is to use 7.7kg of sodium tripolyphosphate, 3.18kg of sodium EDTA, and 379kg of reverse osmosis product water, and adjust the pH value to 10.0 with sulfuric acid.
D. Metal oxide scale is removed by the method of removing calcium carbonate scale.
E. Organic sediments can be removed with 7.7kg of sodium tripolyphosphate, 0.97kg of sodium dodecylbenzene sulfonate, 379L of reverse osmosis product water, and the pH value is adjusted to 10.0 with sulfuric acid. If the pollution is serious, this solution can be soaked for 12 hours.

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

500LPH One Stage RO Drinking Water Systems Water Purification Plant

FAQ:

1. What is the shell film material and specification of drinking water reverse osmosis system?

Material of membrane case: stainless steel and fiberglass (FRP)
Specification of membrane shell: four inch membrane shell 4040 (one core to four core)
8 inch membrane case 8040 (one to seven cores)

2. What are the inlet water quality requirements of drinking water reverse osmosis system?

Inlet water quality requirements:
Turbidity (NTU) ≤1, SDI ≤5 Residual chlorine (mg/L) ≤0.1, Fe2+ (mg/L) ≤4, TOC (mg/L) ≤3


Product Tags:

500LPH RO Drinking Water Systems

      

Drinking Water Reverse Osmosis System

      

One Stage RO Drinking Water Systems

      
Best 500LPH One Stage RO Drinking Water Systems Water Purification Plant wholesale

500LPH One Stage RO Drinking Water Systems Water Purification Plant Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jufu Water Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)